RegsUPby Anemon Innovation

GUIDE TO WORKING WITH REGULATIONS

Keep electric safety and electromagnetic compatibility as distinct review subjects.

An electric vehicle file can contain battery information, electrical drawings and electromagnetic test reports. Putting those documents in one folder does not show which question each one answers. Build a short evidence map before planning tests or discussing an application. This guide recommends a filing and review method, not a test programme for a particular vehicle.

Start with the purpose of each regulation

UN R100 concerns specific safety requirements for the electric power train. UN R10 concerns electromagnetic compatibility, including emissions and immunity. These are different subjects. A report addressing one does not by itself establish that the other has been assessed. Read the relevant scope and selected edition before assigning evidence to either subject.

Describe the configuration that the evidence represents

Identify the vehicle type, intended market, electric drive, rechargeable energy storage system and charging arrangement. Add the part numbers and revision levels of the components relevant to your review. A clear configuration description makes it easier to see whether a supplier report describes the equipment actually fitted to the vehicle.

  • Keep an electrical architecture drawing with the component list.
  • Record the battery, inverter, charging equipment and relevant electronic units included in the review.
  • Identify the vehicle operating and charging configurations represented by each available report.

Make the link from report to vehicle visible

Create a table with one row per report: subject, test object, equipment identification, software or hardware revision, tested configuration and stated limitations. Separate vehicle-level evidence from component-level evidence. Where a document describes a component, record how its installation in your vehicle is represented. Do not infer a wider test scope from the supplier’s product name.

For example, replacing an inverter may leave some documents unchanged while raising new questions about the electrical arrangement and EMC configuration. Record what changed and ask the technical service which existing evidence remains relevant. This example is a review prompt; it does not prescribe retesting or decide the approval consequences of the change.

Turn gaps into precise review questions

  • Which report and configuration support each conclusion in the file?
  • Does a limitation exclude the installation or operating mode you intend to use?
  • Which points need confirmation from the technical service before you finalise the evidence plan?

Keep open questions separate from accepted results. Use RegsUP’s regulation summaries and linked official sources to locate the relevant text. Compare access plans by their published scope if you need ongoing reading access. Neither a reading plan nor this guide replaces the complete technical assessment, applicable tests or the approval authority’s decision.

Read the UN R100 scope and sources →

Read the UN R10 scope and sources →

Compare access plans →